Appliance wattage chart: running and starting watts

49 appliances, each with a cited source. Starting watts are the brief surge a motor needs to start; running watts are what it draws while operating.

Read this first. All values are approximate as published by the source. Check the label on your own equipment. Rows tagged estimate come from third-party sites and are typical values, not our measurements. Where a source gives a range, the calculators use the upper end so you don’t undersize.
ApplianceCategoryRunning WStarting WBasisSourceNotes
Refrigerator or freezer (ENERGY STAR)Kitchen132–1921,200approx. (manufacturer)Honda Power EquipmentHonda lists a second example elsewhere (1,600 start / 200 run); see our fridge article.
Refrigerator (typical range)Kitchen150–400800–1,200approx. (manufacturer)Champion Power EquipmentCalculators use the upper end.
FreezerKitchen100–500500–1,000approx. (manufacturer)Champion Power EquipmentCalculators use the upper end.
Microwave oven, 650 WKitchen1,0001,000approx. (manufacturer)Honda Power EquipmentRated output watts are lower than the watts drawn from the outlet.
Microwave oven, 1,000 WKitchen1,5001,500approx. (manufacturer)Honda Power EquipmentChampion lists a broader 600–1,200 W range for microwaves.
Coffee maker (4-cup)Kitchen600600approx. (manufacturer)Honda Power Equipment
Dishwasher (cool-dry cycle)Kitchen216540approx. (manufacturer)Honda Power EquipmentHeated cycles draw far more; see next row.
Dishwasher (heated cycle)Kitchen1,200–2,400—approx. (manufacturer)Champion Power EquipmentNo starting figure listed by source.
Electric fry panKitchen1,5001,500approx. (manufacturer)Honda Power Equipment
Electric range, one 8-inch elementKitchen2,1002,100approx. (manufacturer)Honda Power EquipmentChampion lists 1,200–2,400 W per burner. Usually a 240 V appliance.
Window AC, 5,000 BTUHeating & cooling450–600900–1,200approx. (manufacturer)Champion Power EquipmentCalculators use the upper end.
Window AC, 10,000 BTUHeating & cooling1,5002,200approx. (manufacturer)Honda Power EquipmentChampion lists 900–1,200 W running / 1,800–2,400 W starting for the same size.
Central AC, 2-tonHeating & cooling2,000–2,5003,500–4,500approx. (manufacturer)Champion Power EquipmentUsually 240 V. Calculators use the upper end.
Central AC, 3-tonHeating & cooling3,000–3,5005,000–6,000approx. (manufacturer)Champion Power EquipmentUsually 240 V. Calculators use the upper end.
Central AC, 4-tonHeating & cooling4,000–5,0006,500–8,000approx. (manufacturer)Champion Power EquipmentUsually 240 V. Calculators use the upper end.
Furnace fan (gas/oil), 1/8 hpHeating & cooling300500approx. (manufacturer)Honda Power Equipment
Furnace fan (gas/oil), 1/4 hpHeating & cooling6001,000approx. (manufacturer)Honda Power Equipment
Furnace fan (gas/oil), 1/3 hpHeating & cooling7001,400approx. (manufacturer)Honda Power Equipment
Furnace fan (gas/oil), 1/2 hpHeating & cooling8752,350approx. (manufacturer)Honda Power EquipmentChampion lists 300–800 W running / 800–1,600 W starting for a 1/2 hp furnace fan.
Space heater (electric)Heating & cooling750–1,500—approx. (manufacturer)Champion Power EquipmentResistive load; no extra starting watts listed.
Electric water heaterHeating & cooling4,5004,500approx. (manufacturer)Honda Power EquipmentChampion lists 3,000–4,500 W. Usually 240 V.
Window fanHeating & cooling50–200—approx. (manufacturer)Champion Power Equipment
Ceiling fanHeating & cooling15–75—approx. (manufacturer)Champion Power Equipment
Sump pump, 1/3 hpWater & garage8001,300approx. (manufacturer)Honda Power EquipmentChampion lists 500–800 W running / 1,000–1,600 W starting.
Sump pump, 1/2 hpWater & garage1,0502,150approx. (manufacturer)Honda Power EquipmentChampion lists 800–1,050 W running / 1,300–2,150 W starting.
Well pump, 1/2 hpWater & garage750–1,0001,500–2,000approx. (manufacturer)Champion Power EquipmentCalculators use the upper end.
Well pump, 1 hpWater & garage1,000–2,0002,000–4,000approx. (manufacturer)Champion Power EquipmentCalculators use the upper end.
Garage door openerWater & garage7201,420approx. (manufacturer)Honda Power Equipment
Washing machineLaundry500–1,0001,000–2,300approx. (manufacturer)Champion Power EquipmentHonda lists 1,200 W for an automatic washer.
Electric clothes dryerLaundry5,4006,750approx. (manufacturer)Honda Power EquipmentChampion lists 4,000–6,000 W. Usually 240 V.
Television, flat-screen 20"Electronics & comms120120approx. (manufacturer)Honda Power Equipment
Television, flat-screen 46"Electronics & comms190190approx. (manufacturer)Honda Power EquipmentChampion lists 80–400 W for 32"–55" TVs.
Laptop computerElectronics & comms200–250200–250approx. (manufacturer)Honda Power Equipment
Desktop computerElectronics & comms600–800600–800approx. (manufacturer)Honda Power Equipment
Monitor (LCD)Electronics & comms3030approx. (manufacturer)Honda Power Equipment
PrinterElectronics & comms400–600400–600approx. (manufacturer)Honda Power Equipment
RadioElectronics & comms50–20050–200approx. (manufacturer)Honda Power Equipment
Internet router / modemElectronics & comms10–20—approx. (manufacturer)Champion Power Equipment
Phone / laptop chargerElectronics & comms20–100—approx. (manufacturer)Champion Power Equipment
Home security systemElectronics & comms15–40—approx. (manufacturer)Champion Power Equipment
CPAP machine (no heated humidifier)Medical & lighting30–60—approx. (manufacturer)Champion Power EquipmentMedical-device users: confirm your own device’s rating and plan backup power with your provider.
CPAP machine (heated humidifier)Medical & lighting60–120—approx. (manufacturer)Champion Power EquipmentSame caution as above.
LED light bulb (each)Medical & lighting8–15—approx. (manufacturer)Champion Power Equipment
Wi-Fi access point (not PoE-powered)Home lab (estimates)6–12—estimateRACKDENSITYIdle–load typical values; measure your own with a plug meter.
Switch, 8-port unmanagedHome lab (estimates)4–5—estimateRACKDENSITYIdle–load typical values.
Router / firewall applianceHome lab (estimates)12–18—estimateRACKDENSITYIdle–load typical values.
Mini PC, Intel N100-class (light load)Home lab (estimates)8–10—estimateMiniPCLabMiniPCLab lists ~5.5–6.5 W idle and 14–18 W full load for N100 mini PCs.
Mini PC, 6–8 coreHome lab (estimates)12–50—estimateRACKDENSITYIdle 12 W / load 50 W typical values.
NAS, 4 bays, HDDs spinningHome lab (estimates)30–45—estimateRACKDENSITYIdle–load typical values.

Dash (—) = the source lists no separate starting figure (calculators treat starting = running).

Cheat sheet of running and starting watts for common household appliances
Wattage cheat sheet (Honda and Champion published figures; approximate). Download the image.

Methodology